Certains contenus, documents et vidéos sont disponibles uniquement en anglais.
HDI polyisocyanate

Drodur 3175B

Blocked HDI-based isocyanate containing 75% solids.

Selection properties
Blocked NCO content
11.1 approx%; ISO 11909
Viscosity @ 25°C (Brookfield)
2900 - 3700cP; ASTM D 2196
Free NCO content
< 0.2%; ISO 11909
Non-volatile content
73 - 77%; ISO 3251
Conseil d’application et approvisionnement
WHAT IT OFFERS

Caractéristiques principales

  • Blocked isocyanate based on HDI
  • 75% solids
MAKE YOUR SHORTLIST

Convient-il à votre formulation ?

A blocked HDI-isocyanate route for one-component stoving coatings.

What decides the fit
Read blocked and free NCO separately; establish the bake schedule with the full coating formulation.
Bring to your trial
Which binder, oven schedule and substrate temperature will the one-component coating trial use?
Propriétés à examiner ensemble
WHERE IT FITS

Applications

  • 1K stoving coatings
GRADE DETAILS

Données techniques

Read every value with its unit and test conditions.

Source: TDS, 1st January, 2026 Ver.- 1. Values and test methods are as stated in this TDS.

Documents & samples ↑
PropertyValue / rangeUnit & test conditions
AppearanceClear liquidVisual
Color1 maxCGS; ASTM D 1544
Viscosity @ 25°C (Brookfield)2900 - 3700cP; ASTM D 2196
Blocked NCO content11.1 approx%; ISO 11909
Equivalent weight378 approxUnit not stated in TDS
Non-volatile content73 - 77%; ISO 3251
Free NCO content< 0.2%; ISO 11909
Density @ 20°C1.06 approxg/ml

How to read technical properties · Evaluate the complete formulation in your intended process.