Brochures, videos & documents

Brochures & videos.

Browse portfolio brochures, watch application videos and request technical documents.

Portfolio brochures

DRC Epoxy Systems for Coatings & Adhesives brochure cover

Epoxy Systems for Coatings & Adhesives

Preview contents
  • Polyamide, polyamine and waterborne curing agents
  • Phenalkamine and phenalkamide curing agents
  • Epoxy resins, esters and reactive diluents
  • PVB, aldehyde, ketone and phenolic resins
Request brochure
DRC Printing Inks brochure cover

Printing Inks

Preview contents
  • Co-solvent and alcohol-soluble polyamides
  • Ketonic, ketone-aldehyde and polyurethane resins
  • Adhesion promoters and PVB
  • Rosin-modified phenolic and UV resins
Request brochure
PRODUCT DOCUMENTATION

Technical & safety data

Choose a grade to review its published profile and request the current TDS or SDS.

Choose a grade
APPLICATION SUPPORT

Prepare your evaluation

Share your application, selected grades and delivery country to discuss samples or technical support.

EXPLORE FURTHER

Application guides & films

Open a topic when you need more detail.

Product selection guides
FROM PROPERTIES TO A SHORTLIST

Make the comparison count.

Open a practical guide to connect the application, component role and published data.

CASE / POLYOLSCompare polyols on a common basis.Use hydroxyl value and viscosity together, then review the intended reactive system.

Compare polyols on a common basis.

  1. Choose the component role

    Start with the intended polyurethane system. Keep castor-oil polyols, co-polyols, emulsions and modifiers in their respective formulation roles when building the shortlist.

  2. Read the properties together

    Review hydroxyl value, equivalent weight, supplied viscosity and moisture where published. Keep the units, temperature and test method beside each value.

  3. Confirm the complete formulation

    Review the proposed co-reactant and its stated mixing basis. Evaluate the selected components in the intended application; supplied-polyol viscosity does not describe the mixed formulation.

WORKED READING EXAMPLE

Two castor-oil polyols, different published profiles.

These rows let you compare hydroxyl value and viscosity on the stated basis. They do not, by themselves, establish which grade meets the finished-system requirements.

Drothane 1145

Viscosity @ 25°C (Brookfield)
2700 - 3200cP; ASTM D 2196
Hydroxyl value
220 - 250mg KOH/g; EN ISO 4629

Drothane 1150

Viscosity @ 25°C (Brookfield)
3000 - 4000cP; ASTM D 2196
Hydroxyl value
150 - 165mg KOH/g; EN ISO 4629
CASE / EPOXY SYSTEMSRead the resin and curing agent as a pair.Keep component identity, mixing basis and cure conditions connected.

Read the resin and curing agent as a pair.

  1. Separate the component roles

    An epoxy resin, curing agent and reactive diluent do different jobs. Select candidates within the role you need, then review the proposed resin–curing-agent combination.

  2. Retain the mixing basis

    Read resin equivalent weight, curing-agent AHEW and any published mixing ratio together. A ratio naming one resin basis is not a universal ratio for all epoxy resins.

  3. Define the trial conditions

    Record the application temperature, mixed quantity, part or coating geometry and cure schedule. Read gel time with its stated temperature and sample size, separately from the working time needed for your process.

WORKED READING EXAMPLE

A mixing ratio carries its resin basis.

The Dromide 9331 ratio names an epoxy resin with EEW 190. Its gel-time row also states the temperature and sample size. Keep those details in the evaluation brief when discussing the selected pair.

Explore the mixing and gel-time examples

Dromide 9331

Mixing ratio with epoxy resin (EEW 190)
65phr
Gel time @ 25°C (150 gms)
115 - 125min
PRINTING INKSDefine the printed construction before the resin.Connect printing process, ink position and converting requirements.

Define the printed construction before the resin.

  1. Start with the process

    Identify flexo or gravure, offset, or a UV / EB formulation. Include the substrate, surface treatment and carrier or curing system.

  2. Locate the ink in the construction

    For surface printing, describe the exposed printed surface. For a laminated structure, include the film, ink, adhesive or extrusion process and second web.

  3. Identify the component you need

    Distinguish the primary binder, co-resin or modifier, and reactive component. Review solvent or solubility, solids and solution properties on their stated basis before comparing candidates.

SURFACE PRINTING

What will the printed surface face?

  1. Substrate & treatment
  2. Ink & drying or cure
  3. Exposed print & handling

Include the intended handling, drying conditions and tests for the printed surface.

Explore flexo & gravure
LAMINATED CONSTRUCTION

What surrounds the ink?

  1. Film & print position
  2. Adhesive or extrusion process
  3. Second web & converting

Evaluate the ink within the complete construction and its converting conditions.

Explore lamination inks
Application guides
Explore worked application examples Flooring · Waterproofing · Printing Inks

Work through an application example.

Connect a formulation task to documented grades and the questions for your evaluation.

All application guides 18 guides

Application films

Watch our company film
Read the film transcript

This cured sheet bends in the hand. It illustrates the flexibility a formulator can design into a two-part polyurethane coating. On steel, a coating needs to adhere to the surface it protects. This chemistry can be used to formulate anti-corrosion coatings. The first component is a pale yellow, solvent-free polyol made from castor oil. It contributes flexibility and adhesion. Its water-repellent character is also useful in protective coatings. The viscosity tells us how the polyol flows. The hydroxyl value helps the formulator calculate the hardener requirement. The second component is a modified MDI hardener. It has a lower viscosity, and an isocyanate content of twenty-five to twenty-eight percent. When the two parts are mixed, hydroxyl groups on the polyol react with isocyanate groups on the hardener. These links build a polyurethane network as the coating cures. On prepared concrete, this chemistry can be formulated into primers, sealers and flexible, water-resistant coatings. An indoor court is another development concept. Surface grip and impact absorption must both be tested on the complete flooring system. For a formulation trial, start with the substrate and the conditions the coating will face. Contact D.R. Coats for samples, technical data and formulation support.

How to read technical data
SELECTION ESSENTIALS

Read a technical value.

Select an example to see which details belong together when comparing grades.

Drothane 1145

Viscosity @ 25°C (Brookfield)

2700 - 3200

cP; ASTM D 2196

Open this product profile

Read viscosity with its conditions.

Published range
2700 - 3200
Unit
cP
Temperature
25°C
Instrument / method
Brookfield; ASTM D 2196

Keep the range, temperature and method together when comparing published viscosity values. This row describes the supplied grade; it is not a prediction of the viscosity of your complete formulation.